Re-tested 24 hours before it ships
A unit marked 4.2 kilowatts on the carton delivers about 1.95 kilowatts once the water is at 5 degrees and its condenser is standing in 34-degree air. That is not a factory error. It is how cooling capacity is measured, and almost nobody selling these explains it.

Cooling capacity is measured under standard test conditions: 15-degree water in, 27-degree ambient air. An ice bath is a far harder job. The colder the water, the lower the refrigerant evaporating temperature, and the less refrigerant mass the compressor moves per revolution. Add a condenser standing in 34-degree air, which raises discharge pressure, and real output lands at about 46 per cent of the brochure number. Every PK figure quoted anywhere on this site already accounts for that, so the 1.5 PK we name behaves like 1.5 PK in your garden rather than in a test chamber.
| Size | Brochure | Real output at 5 °C | Max volume, lid on | Draw | Price |
|---|---|---|---|---|---|
| 0.5 PK | 1.4 kW | 0.65 kW | 110 L | 480 W | Rp 14 million |
| 0.75 PK | 2.1 kW | 0.98 kW | 180 L | 700 W | Rp 16.5 million |
| 1.0 PK | 2.8 kW | 1.3 kW | 260 L | 950 W | Rp 19 million |
| 1.5 PK | 4.2 kW | 1.95 kW | 410 L | 1400 W | Rp 26 million |
| 2.0 PK | 5.6 kW | 2.6 kW | 570 L | 1850 W | Rp 34 million |
| 3.0 PK | 8.4 kW | 3.9 kW | 1100 L | 2700 W | Rp 48 million |
The maximum volume column is the largest tub that unit can still hold at 5 degrees in hot lowland Indonesia with the lid on — 33-degree air, 29-degree mains water. In Bandung that figure rises about 20 per cent, in Berastagi about 45 per cent. For your own city, run the chiller calculator, which uses the same model as our survey sheet.
A chiller has to pass both. First, its real output at the target temperature must be at least twice the tub's holding load. That margin is not there to sell you a bigger unit; it exists because a compressor running flat out all day ages fast, and the hottest day of the year is not the average day. Second, it must pull a full tub from local mains temperature down to target within eight hours, so a first fill can run overnight. A 400-litre tub in Jakarta with a 516-watt load therefore lands on 1.5 PK rather than the 1 PK that a holding calculation alone would allow.
If the tub is near a bedroom, 52-58 dB at one metre will be audible and the compressor will start a dozen or more times a day. If your local voltage regularly falls below 190 volts, an on-off unit will struggle. In both cases the Arctic inverter chiller is the better answer despite the price. And never use a quarter or half-PK aquarium chiller on an ice bath: those are designed for a 200-litre tank in an air-conditioned room and in an open garden they hold water at 16-19 degrees.
Re-tested imported units run Rp 14-48 million from 0.5 to 3 PK, including installation in Java and Bali, insulated hose to six metres, the mounting plinth and the on-site cold test. If your tub was built by somebody else we still measure it and calculate its load first — an uninsulated tub can need a chiller twice the size. Full comparison with the inverter line and every other price is on the pricing page.
Yes, and that is about a quarter of our chiller sales. Send photographs, internal dimensions and whether the walls are insulated. If they are not, we will tell you what PK that implies and usually suggest adding external insulation first, because it is far cheaper than going up two sizes.
Eight to twelve years for a compressor on stable voltage with the fins washed on schedule. What ages first is normally the circulation pump, at five to seven years, and replacing one costs under Rp 2 million.
Usually not. Holding cold water costs 4.9 kWh a day on a 400-litre tub; cooling it again from scratch costs about 3 kWh in one go plus eight hours of waiting. If you immerse three times a week or more, leave it running.
Yes. R32 is used across new domestic air conditioning, so it is available almost everywhere including district towns. That availability is one of the reasons we chose it over refrigerants stocked only in big cities.
The water stops falling at some temperature, usually 9 to 14 degrees, while the compressor runs without pause. Its life shortens, the electricity bill is higher than a correctly sized unit, and the result is still wrong. That is why we decline to sell a unit smaller than the calculation, even when asked.
Other products

Our own inverter line: ±0.3 degrees of drift, under 48 dB while holding, and it runs from 180 volts.
View →
Accessory list with the technical reason to buy or skip each one, plus four products we decline to sell.
View →
Insulated folding tub, usable in twelve minutes, packs down to 14 kg: buy it to test the habit, not to keep forever.
View →Pesan Ice Bath Chiller
We reply with sizing, the right chiller and a full price.